
MasterSeal 591 | Hydroseal and quick concrete repair
Cement repair mortar to stop active water leakage
MasterSeal 591 | One-component, ultra -fast curing repair mortar, based on special cements and fine aggregates, designed to quickly repair active leaks.
-
May be used in contact with drinking water.
- Complies with EN 1504-3.
Application area
-
For internal and external works.
-
To stop water filtration through cracks in structures.
-
For sealing joints in structures and floors, as a primary treatment before waterproofing basements and basements with MasterSeal products.
-
For sealing structural joints and cracks in tanks and other structures intended for storing water, including drinking water.
-
For fast sealing of cracks and holes.
-
For fast sealing of holes from fixing the climbing formwork.
- For fast fastening of bolts, anchors, pipes, sanitary fittings and other elements.
Features and Benefits
-
One-component, miscible only with water.
-
Ultra-fast stop of leaks (hardening start time 1-2 minutes).
-
Expands and forms a waterproof structure.
-
Can be covered with waterproofing materials after 15 minutes.
-
Does not contain chlorides, does not cause corrosion of steel.
-
Mechanical characteristics are identical to heavy concrete.
-
Ultra-fast hardening allows quick and easy sealing of cracks and holes.
-
No injection equipment required.
-
Based on cement, does not contain toxic elements.
- Can be used in contact with drinking water.
Specifications
|
Material |
Min. fillers, polymer-modified additives, special cement
|
|
Color |
Grey
|
|
Adhesion strength (EN 1542) |
≥0.5N/mm2
|
|
Compressive strength 30 min |
≥7 N/mm2
|
|
24h |
≥10 N/mm2
|
|
28d |
≥30 N/mm2
|
|
Application temperature |
+5°С +25°С
|
|
Maintaining mobility |
1-1.5 minutes
|
|
Curing time |
2-3 minutes
|
|
Packing |
5 kg
|
Foundation preparation
-
The base must be clean and solid.
-
Before applying the material, the surface should be thoroughly moistened with water.
-
Places of active water filtration must be expanded with a perforator or manually by at least 20 mm in width and depth, remove all weakened concrete particles.
Mixing ratio
-
MasterSeal 591 5kg /water 1.2-1.4 l.
- The density of the mixture is 2.14 kg/l.
-
It is necessary to work in rubber protective gloves!
-
Pour MasterSeal 591 into a clean mixing container and add water in the amount of ≈0.24-0.28 l of water per 1 kg.
-
Mixing must be done manually with a spatula until a plastic mass is obtained.
-
It is necessary to mix thoroughly and quickly to a viscous dense consistency.
-
Do not mix the frozen mixture again.
-
The prepared solution must be given a conical shape in the hands.
-
When forming the material, rubber gloves must be used.
-
After the setting process has begun, the previously shaped material is pressed firmly by hand into the breakthrough site.
-
Pressure should be applied for approximately 1 minute.
-
Do not withdraw your hand, trowel or spatula too quickly during application.
-
Twisting movements must not be made while sealing holes with material.
- Excess material should be removed with a trowel or spatula.
Attention
-
The material must not be applied to frozen surfaces.
-
Material application temperature from: +5°С to +35°С.
-
The material must not be used to fill active cracks.
-
Do not use material to fill expansion joints.
-
Re-hardened material must not be stirred.
- Do not use the material if hard lumps have formed in it.
Important aspects when applying
-
The air temperature and the substrate temperature must be at least 5º C or not more than 25º C.
-
MasterSeal 591 gains strength very quickly.
-
Moisturize it within 30 minutes after application.
-
The coating must be protected from direct sunlight, wind, frost or rain for 24 hours.
-
The application time of cement systems depends on the temperature and relative humidity of the air.
-
At low temperatures, the reaction slows down, which increases the working time and setting time.
-
High temperature speeds up the reaction and the times mentioned above are reduced.
-
In order for the material to harden, the temperatures of the material, substrate and air cannot be less than the minimum permitted temperatures.
- When applying the material in the cold, use hot mixing water, at least +25°C.
Cleaning tools
-
Clean tools and equipment with warm soapy water after use.
- Once MasterSeal 591 has hardened, it can be mechanically removed from the surface.
Package
Canister: 5 kg.
Storage
-
Store in original, unopened packaging in cool, dry conditions, protected from frost.
-
For short-term storage, a maximum of 3 pallets can be stacked one on top of the other.
-
For long-term storage, pallets cannot be stacked one on top of the other.
Best before date
-
The guaranteed shelf life of MasterSeal 591 in unopened undamaged packaging is 6 months.
-
Store only on pallets covered with stretch film in a dry place.
-
Protect from direct sunlight and rain.
-
Failure to comply with the recommended storage conditions may result in damage to the material or packaging.
- Opened packages must be tightly closed immediately and used within one week after opening.
Security measures
-
Do not approach storage facilities during a fire;
-
Store products in well-ventilated areas;
-
During work, work clothes, protective gloves, goggles and a mask should be used in accordance with health and safety regulations;
-
Since uncured materials have an irritating effect, contact of the components with the skin and eyes should not be allowed, and in case of contact, rinse with plenty of water;
-
If swallowed, seek medical attention immediately;
-
It is forbidden to bring food and drink to the construction site where the product is used;
-
The product must be kept out of the reach of children.






