Epoxy, anchoring, adhesive repair compound for concrete floors 

Repair of expansion joints

Warehouse concrete floor repair

Garage floor repair

Repair of cracks in concrete

Description
Characteristics
Application

MasterBrace ADH 1406 | Epoxy, repair, anchoring and adhesive mixture of thixotropic type, for concrete floors, two-component.

Complies with EN 1504-4 / 1504-6.

Application area

  • Installation of chemical anchors in brick and concrete;

  • Repair and filling of wide cracks;

  • Bonding various types of materials such as steel, concrete, brick, polymeric materials, etc.;

  • Installation of injection packers;

  • Installation of reinforcing bars and seismic protection in concrete structures, on bridges and viaducts;

  • Bonding of elastic waterproofing tape MasterSeal 930, for expansion joints in concrete.

  • Repair of concrete floors.

  • Restoration of concrete floors.

  • Seam edge repair.

  • Warehouse concrete floor repair.

Features and Benefits

  • Thixotropic pasty consistency;

  • Excellent adhesion to many materials, incl. steel, concrete; 

  • Chemical resistance;

  • Vapor and waterproof;

  • Excellent adhesion to damp concrete substrate;

  • Does not contain solvents;

Specifications

MasterBrace ADH 1406 Comp A               

Epoxy resin

 

MasterBrace ADH 1406 Comp B

Hardener

 

Color    

Grey

 

Mix Density

1.7±0.05kg/l

 

Compressive strength TS EN 196

1 day 30 N/mm2

 

7 days 75 N/mm2

Flexural strength TS EN 196

1 day 17 N/mm2

 

7 days 25 N/mm2

Material application time

40 min

 

Reapplication interval

18-24 hours

 

Operating temperature

-15°С...+90°С

 

Full hardening at 20o C

7 days

 

Foundation preparation

  • The base must be level, clean and dry and sound;

  • Concrete must be free from ice, film of polymer compositions, condensate, oil stains, cement laitance, loose material and dust;

  • If there is a water leak, it must be dewatered or cracks properly sealed;

  • Chips along the edges must be contoured at an angle of 90 °.

Preparing the mixture

  • The material consists of two components packed in metal pails;

  • The temperature of the material must be in the range of 15°C - 25°C before mixing;

  • Add component B to component A without residue and mix with a low speed mixer at 300 rpm for 3 minutes until a homogeneous mixture without lumps is obtained.

  • The prepared MasterBrace ADH 1406 solution is applied to the previously prepared surface with a steel spatula;

  • The application thickness is 2-30 mm;

  • To install anchors, the diameter of the hole must exceed the diameter of the anchor by 6 mm;

  • Thoroughly clean the holes with a brush and blow with compressed air;

  • Mixed material, place in a gun with an appropriate spout and squeeze into the hole;

  • Fill the hole to half the depth;

  • Install the anchor with slow rotation in one direction.

Consumption

1.7 kg/m2/per 1 mm layer thickness.

Special remarks

  • The temperature of application of the material is from +5 to +30°C;

  • The application and hardening time of materials based on polymer resins varies depending on relative humidity, ambient temperature and substrate;

  • The reaction slows down at low temperatures, leading to an increase in the period of work with the mixture and the setting time;

  • On the other hand, high temperatures speed up the reaction, which leads to a reduction in the working time with the mixture and the setting time;

  • For complete hardening of the material, the temperature of the base and the environment must not be lower than the permissible operating temperature.

  • The material is supplied in the form of components measured in exact quantities for mixing;

  • Do not violate the ratio of components and do not add foreign components, solvents to the mixture;

  • Stir only with a suitable electric tool, do not mix by hand.

Tool cleaning

  • After completion of work, all tools must be cleaned with solvents;

  • After hardening, it can only be cleaned mechanically.

Package

  • MasterBrace ADH 1406 comp A - 3.75kg;

  • MasterBrace ADH 1406 comp B - 1.25kg

Storage

Should be stored in the original container, in a cool and dry place, indoors at a temperature between +5o C and +25o C.

Best before date

18 months, from date of manufacture, under appropriate conditions.

Security measures

  • Do not approach storage facilities during a fire;

  • Store products in well-ventilated areas;

  • During work, work clothes, protective gloves, goggles and a mask should be used in accordance with health and safety regulations;

  • Since uncured materials have an irritating effect, contact of the components with the skin and eyes should not be allowed, and in case of contact, rinse with plenty of water;

  • If swallowed, seek medical attention immediately;

  • It is forbidden to bring food and drink to the construction site where the product is used;

  • The product must be kept out of the reach of children; 

  • See Material Safety Data Sheet for more information.

Top effective solutions
CEMTOP 350
Finish coating for intensive loads
0.00 UAH/25 кg
HURRICANE V2
Industrial vacuum cleaner
0.00 UAH/ед.
VIMATOL-SPL
Superplasticizer for concrete
0.00 UAH/1 кg
CEMPRIME AC
Acrylic primer for concrete
0.00 UAH/25 кg