BOTAMENT BE 89

BOTAMENT BE 89 | Floor waterproofing before screed

Elastic bituminous waterproofing for concrete floors and screeds

Basement floor waterproofing

Cellar floor waterproofing

Bridge waterproofing

PROFESSIONAL CONSULTATION
more than 15 years of experience
WARRANTY FROM THE SUPPLIER
expiration date control

COMPLETE SUPPLY
complete project package

FAST DELIVERY
transport companies, courier services

HIGH QUALITY
goods from the world's leading manufacturers

LOYALTY PROGRAM
partner prices for regular customers
Description
Characteristics
Application

BOTAMENT BE 89 | Elastic waterproofing membrane, based on modified bitumen emulsion, for waterproofing structures and building elements.

  • BOTAMENT BE 89 is applied efficiently and economically using the airless spray method;

  • The material does not contain abrasive fillers, therefore it protects equipment from damage and excessive wear;

  • BOTAMENT BE 89 can be used to restore old roofs and open terraces, including those made from roofing material;

  • To perform new waterproofing of foundations, to protect concrete floors, cement screeds, from the effects of capillary moisture.

  • Horizontal waterproofing and protection of structures;

  • In case of intense UV radiation, it is recommended to sprinkle the fresh coating with dry sand with a fraction of 1-4 mm to protect the waterproofing;

  • The material has good adhesion to concrete, plasters of classes CS II, CS III and CS IV in accordance with EN 998-1, sand-lime bricks, cellular concrete, hollow bricks, concrete blocks, pumice, wood, steel and roofing material;

  • BOTAMENT BE 89 is resistant to weathering and aggressive substances, spreading in the soil, in accordance with DIN 4030.

Properties

  • Elastic, covers cracks;

  • Can be applied by brush, roller or spray;

  • For external and internal works;

  • High stability at high and low temperatures;

  • Does not contain solvents.

Areas of use

Technical data

Material composition

Water based bituminous emulsion

 

Package

Plastic bucket 10 l, 30 l

 

Storage

In a cool, frost-free place, at least 12 months, in hermetically sealed original packaging

 

Density

1.05 kg / l

 

Temperature resistance

from - 20 ° С to + 80 ° С

 

pH

9

 

Elongation at Break

500%

 

Drying time before applying the next layer

24 hours

 

 

Drying time before backfilling the pit

3 days

 

Cost per layer

1.1 l / m2 / mm

 

Temperature application surface

From + 5 ° С to + 30 ° С

 

Cleaning products

Solvent

 

Foundation preparation

  • Substrate: dry, clean and unfrozen, free from grease, oil, paint, cement laitance, delamination and construction debris;

  • There should be no protruding parts on the base, the edges of the elements must be cleaned of construction debris and dirt;

  • At the outer corners, it is necessary to make chamfers, and in the inner corners, arrange fillets from the mineral solution;

  • Steel substrates must be clean (standardized purity grade SA 2 ½ in accordance with DIN EN ISO 12944-4);
  • When applying the material to masonry, the masonry joints must be completely filled with mortar;

  • Absorbent, bituminous substrates must be primed with BOTAMENT BE 901 primer;

  • Bituminous substrates should be primed with BOTAMENT B 97 L and sprinkled over the fresh layer with dry sand, with a grain size of about 0.5 mm;

  •  Before applying the base coat of waterproofing, the base coat must be completely dry;

  • Substrates with low strength, such as cellular concrete, must be primed with BOTAMENT D 12 primer;

  • When applying BOTAMENT BE 89 by airless spray, the substrate must be primed.

Application

  • Before using BOTAMENT BE 89, the material must be mixed;

  • It is necessary to apply waterproofing, from the side of exposure to water; 

  • For coating roofs, brush, roller or spray equipment can be used;

  • When applying, it is necessary to carefully cover the surface of the inner and outer corners;

  • Waterproofing must be done in at least 2 layers;

  • The drying time of one layer is about 24 hours;

  • The next layer can be applied only after the previous one has dried;

  • It is possible to fill up the pit only after the last layer of waterproofing and the installation of a protective, drainage coating have completely dried;

  • Waterproofing protection must be performed in accordance with existing standards and regulations. 

  • To do this, we recommend using the BOTAMENT DS 993 drainage slab.

Recommendations

  • Exposure to direct sunlight can lead to softening of the coating and the formation of bubbles;

  • Prolonged exposure to the weather must be avoided, so this can lead to cracking of the surface;

  • The technical recommendations of all materials used with BOTAMENT BE 89 must be followed;

  • For optimal results, we recommend a trial application of the material before use.
Top sales
Squeegee for screed
Squeegee for screed 6-30 mm
0.00 UAH/ед.
VIMAPUR VARNISH
Solvent polyurethane varnish
0.00 UAH/10 кg
VIMAPUR PRIMER-W
Water-based polyurethane primer
0.00 UAH/5 кg
VIVALTOP CURE ECO
Membrane-forming acrylic varnish
0.00 UAH/20 кg